Reliability test report
1 Humidity
The device shall be placed in 90%~95% relative humidity and at 60℃±3℃ for 48h, then place at 25℃±5℃ and less than 65% relative humidity for 2h
It shall fulfill the specification
2 High Temperature
The device shall be placed at 105℃ for 48h, then place at 25℃±5℃ and less than 65% relative humidity for 2h
It shall fulfill the specification
3 Low Temperature
The device shall be placed at ‐40℃ for 48h, then place at 25℃±5℃ and less than 65% relative humidity for 2h
It shall fulfill the specification
4 Temperature Cycle
The device shall be placed at ‐40℃ for 30 min then at 105℃ for 30 min. Cycling shall be repeated 5 times. At the room temperature for 1h
It shall fulfill the specification
5 Salt Spray Test
The device shall be placed in salt spray box (5% NaCl) at 25℃±5℃ for 24h.
It shall fulfill the specification
6 Vibration Test
The device shall be placed to vibration for 2h each in x,y and z axis with the amplitude of 1.5mm, the frequency shall be varied uniformly between the limits of 10Hz~55Hz.
It shall fulfill the
specification
7 Drop Test
The device shall be dropped naturally to cement floor 6 times from the height 1 meter
It shall fulfill the specification
8 Drawing Force Test
The device shall be placed at push/pull tester at the strength of no less than 10N
It shall fulfill the specification
9 Voltage Resistance
1.Insulation spark voltage 1.5KV
2.Sheath spark voltage 1.5KV
3.Insulation resistance to sheath voltage 0.5KV
It shall fulfill the specification
Specification
1.Physical Properties
Connect Type.................. SMA-J
Operating Temperature......... -40~85°
Storage Temperature........... -40~95°
2.Electrical Properties
Frequency Range................... 690~960MHz
1400~2170MHz
2300~2700 MHz
Impedance..................... 50Ω
VSWR............................ <2
Efficiency........................ 67%
Peak Gain......................... 4dbI